Model G01075

AC/DC Converter

Efficient converter for industrial automation.

Selectable output;
RoHS Directive;
Short-circuit protection;
Electromagnetic Compatibility (EMC);
Input connection
PCB Terminal Block
Output connection
PCB Terminal Block
Current
3 A
Encapsulation
Open frame
Power
36 W
Protections and standards
Short circuit, IEC CISPR32, IEC 63000
Input voltage
96~242 VAC
Output voltage 1
12 V or 14.5 A
Dimensions
107 x 51 x 40 mm
  • Passive thermal management.
  • Open Frame topology.
  • Short-circuit protection.
  • Operational output flexibility.
  • Compliant with BPP (Basic Production Process)

‍

  • Access Control and Electronic Turnstiles
    Continuous power supply for biometric readers and processing boards in high-traffic systems

  • Industrial Automation

Robust power supply for PLCs, proximity sensors, and relays in control panels where physical space is limited and electrical stability is mandatory.

  • Security and Monitoring Systems

Linear energy support for alarm centers and data communication devices, mitigating failures caused by fluctuations in the external power grid.

‍

How does the system behave under overload or short-circuit conditions?

The device features an active short-circuit protection circuit. Upon detecting an anomaly, the power supply ceases current delivery to preserve the integrity of both the converter and the connected peripheral components, automatically returning to normal operation once the fault is cleared.

Why is the G01075 model supplied as an open frame, and how does this affect installation?

Open-frame topology: A compact design engineered for direct integration into existing enclosures, such as turnstiles and panels. It optimizes physical space, reduces industrial costs, and leverages the enclosure's own airflow for thermal management.

How is the electrical connection made, and what is the recommended wire gauge for the PCB terminal blocks?

Input and output connections are made via PCB-soldered terminal blocks. It supports rigid or flexible cables up to 1.55mm², ensuring low contact resistance and security against disconnections caused by structural vibration.

Do you have any other questions?